Locator impression post,

Description

Made from aluminium with black silicone insert.

Product number: 636067
Questions about the product? We are glad to be here for you!
Product information "Locator impression post,"

For transferring the situation in the mouth to the impression.

Accessories

Locator instrument, three-part,
Screwed stainless steel tip for removing retention inserts, mid section for repositioning the retention inserts, and gold coloured insertion aid for final screwing of the Locator®.
Details
Locator adapter, with contra-angle connector,
Tool for unscrewing the Locator abutment with contra-angle or as an insert in conjunction with 636077 in the torque ratchet.
Details
adapter ratchet for Locator adapter contra-angle,
Tool for manual unscrewing the Locator abutment in conjunction with 636075 in the torque ratchet.
Details
Locator plugin, extended range, 4 pcs./green,
Nylon matrix for insertion into the Locator matrix housing. Without centric retention, 20° divergence compensation, shearing force 1.360-1.800 g.
Details
Locator plugin, extended range, light retention, 4 pcs./red
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 20° divergence compensation, shearing force 220-680 g.
Details
Locator plugin, extra light retention 4 pcs./blue,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 680 g.
Details
Locator replacement plugin, 4 pcs./clear,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 2.260 g.
Details
Locator lab implant,
For transferring the impression situation to the master model.
Details
Locator abutment, D=5.3 mm GH=2.0,
Variante: 5,3 mm / 2 mm
TiN coated assembly for fixing overdentures. Individual axes on the implant may diverge by max, 20° (10° for implants with Ø 3.3 mm) and between two implants by max. 40° (20° for implants Ø 3.3 mm). ,The self-orienteering construction of the Locator® anchoring system supports the patient when inserting and fixing the prosthesis.
Details
Locator matrix set (3 parts),
In the smallest version, the Locator® has a total height of 3.3 mm with a retention housing and nylon insert. ,This makes the Locator® System also suitable in circumstances where vertical space is limited.
Details
Locator plugin, light retention, 4 pcs./pink,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 1.360 g.
Details

Cutsomers also bought

Locator matrix set (3 parts),
In the smallest version, the Locator® has a total height of 3.3 mm with a retention housing and nylon insert. ,This makes the Locator® System also suitable in circumstances where vertical space is limited.
Details
Tizian Blank NEM fine 98 mm
Tizian Blanks NEM (non-precious metal) are made of beryllium-free and cadmium-free CoCr ceramic alloy according to DIN EN OSP 22674 and EN ISO 9693 for applications with thin cross-sections which are exposed to extreme forces. Examples are removable partial dentures, clasps, thin veneered individual crowns, fixed full arch dentures or bridges with small cross-sections, bars, fixations, implant-supported supraconstructions. Properties: Alloy type: 4Density: 8.8 g/cm³Vickers hardness: 285 HV 10/30CTE- value (25-500 °C): 14,4*10-6 K-1Oxidation without vacuum (Point 4c): 1000 °CMass content of the components (in weight-%)*: Co 63, Cr 29, Mo 6 / Mn x, Nb x, Si x, Fe xTensile strength: 680 MPa0.2 % yield point: 400 MPaElongation at break: 9 %E-module: 250 GPa *X= <, 1%
Details
T86/T96 - Speed radius drill 1 mm for CoCr/Titan twin-bladed, 6 mm shaft
T86/T96 - Radius cutter Diameter: Ø 1 mmBlade: double-edgedShaft: Ø 6 mmTotal length: 45 mmBlank material: CoCr, titaniumCoating type: coatedFor milling systems: Tizian 3.5 Series, Tizian Cut 5.2 Pro, Tizian Cut 5.2 Pro Plus, Tizian Cut 5.2, Tizian Cut 5.2 plus, Tizian Cut 5, CORiTEC 550i, CORiTEC 650i
Details
Locator abutment, D=3.3 mm GH=2.0,
TiN coated assembly for fixing overdentures. Individual axes on the implant may diverge by max, 20° (10° for implants with Ø 3.3 mm) and between two implants by max. 40° (20° for implants Ø 3.3 mm). ,The self-orienteering construction of the Locator® anchoring system supports the patient when inserting and fixing the prosthesis.
Details