Filter
The item has been added to your inquiry list
Alphalink Implant, 2 x 4g cartridge incl. mixing cannula
For bonding titanium abutments to individualized zirconium dioxide abutments and supra-constructions. The full system consists of: Sebond Implant: The bonding agent prepares the zirconium dioxide surface for secure bonding. Alphalink Implant: The fixing composite bonds your framework to the abutment. Indications: Glue individual abutments to the corresponding adhesive base. Use this system for secure adhesion of supra constructions to abutments. Bond the following materials: Zirconium dioxide Precious metal Non-precious alloys Titanium Ceramics Unequaled bond strength values: Zirconium dioxide: >, 20 MPa Titanium: >, 30 MPa Benefits at a glance: The material offers the highest level of safety, as it was especially developed for bonding The system adapts to the user: Intraoral use = quick curing Use on models = longer working range High bond strength Long term stability due to the specially adapated formula Saves time Facilitates accurate work:The pasty consistency lets you remove excess material very easily Content: 2 x 4 g syringe Alphalink Implant, 10 mixing tips
torque wrench 4 Ncm,
Using this torque wrench the inner matrix is screwed into the matrix housing and set onto the patrix. Inner assembly matrices with blue acrylic inserts should not be used as permanent inner matrices in prostheses, they are intended exclusively for use in the dental laboratory.
Sebond Implant, 5 ml bottle
For bonding titanium abutments to individualized zirconium dioxide abutments or supra-constructions. The full system consists of: Sebond Implant: The bonding agent prepares the zirconium dioxide surface for secure bonding. Alphalink Implant: The fixing composite bonds your framework to the abutment. Indications: Glue individual abutments to the corresponding adhesive base. Use this system for secure adhesion of supra constructions to abutments. Bond the following materials: Zirconium dioxide Precious metal Non-precious alloys Titanium Ceramics Unequaled bond strength values: Zirconium dioxide: >, 20 MPa Titanium: >, 30 MPa Benefits at a glance: The material offers the highest level of safety, as it was especially developed for bonding The system adapts to the user: Intraoral use = quick curing Use on models = longer working range High bond strength Long term stability due to the specially adapated formula Saves time Facilitates accurate work:The pasty consistency lets you remove excess material very easily Content: 1 x 5 ml Sebond Implant
activator / deactivator,
Using this wrench, the gold inner matrix can be compressed (activated) or expanded to match the position of the prosthesis.
Locator adapter, with contra-angle connector,
Tool for unscrewing the Locator abutment with contra-angle or as an insert in conjunction with 636077 in the torque ratchet.
key for insertion aid (for ratchet) long, width 3,
Variante:
Schlüssel für Eindrehhilfe lang, SW 3
The tool’s working tip fits onto the external hexagon of the insertion post. It can be used by hand, or with the torque ratchet. This long version of the tightening aid can be used in jaws with teeth, in the anterior area. A drilled hole safety cord is located in the turntable of the grip.
screwdriver width 2.3 mm, machine-driven
The screwdriver with contra-angle connection offers a 2.3 mm hex connector. With help of the contra-angle, it is used to screw in two-piece IMPLA implants automatically and directly. The screwdriver 2.3 mm fits exactly into the inner hex of the IMPLA Hex Connection implants to insert them. Furthermore, it serves as a screw-in instrument for SAE cone adaptors.
hex screwdriver long, width 1.2,
Variante:
1,2 mm / lang
The required torque for the retaining screw is exerted with the help of the torque ratchet. This long version of the screwdriver can be used in jaws with teeth, in the anterior area. It has a 1.2 mm hexagon at the tip. A drilled hole for a safety cord is located in the turntable of the screwdriver grip.
hex screwdriver long, width 2.3,
Variante:
lang
This screwdriver with ratchet connection is a 2.3 mm hex and can be used either in connection with the torque ratchet or manually. The screwdriver 2.3 mm fits directly into the inner hex of the IMPLA Hex implants. It is used to adjust the screw-in depth after removing the insertion post (e.g. to correct the position of the hex). What's more, it serves as a screwdriver for SAE cone adapters. The tool has a hole through which it can be secured with a thread.
adapter ratchet for Locator adapter contra-angle,
Tool for manual unscrewing the Locator abutment in conjunction with 636075 in the torque ratchet.
contra-angle adapter width 1.2 mm short,
Variante:
1,2 mm / kurz
This can be used either manually (adapter for elbow instruments 636077) or with the elbow attachment. The short version is used for jaws without teeth, or in cases where the mouth opening is limited. It has a 1.2 mm hexagon at the tip.