Impla 3D Surgery tray,
Used for sterilization and storage in the IMPLA 3D sterilization box (available separately). Dimensions 26.00 cm x 17.00 cm x 2.50 cm (LxWxH). The transparent lid is pushed into the side of the box, which prevents any unintentional opening.
fixation screw kit for template,
Set for attaching drilling templates and bone pads with matching drill bits, elbow piece adapter and matching screwdriver.
Impla 3D sterilization box,
Used for sterilisation and storage of the Impla 3D navigation surgery tray (available separately). Dimensions 27.5 cm x 18.00 cm x 5.00 cm (LxWxH). The removable lid is held in place with two robust metal clips. Labels for management of sterile items can be inserted on the front.
sleeve holder,
The drilling sleeves are clipped into the sleeve holder and secured. The holder can be can be freely rotated through 360°, which makes it suitable for universal use in the patient’s mouth.
Thread cutter 3.3/14.5 mm for IMPLA 3D,
Variante:
3,3 mm / 14,5 mm
By pre-cutting the thread, the final torque is reduced, particularly on the bones D1 and D2, which prevents overheating and excessively strong compression. The thread cutter is used in computer-navigated implantology.
Impla 3D-Navi drill 3.15 mm x 22.5 mm,
Variante:
3,15 mm
22.5 mm long surgical drill for template guided implantation.
countersink cutter 3.3 for IMPLA 3D,
Variante:
3,3 mm
This tool mills the upper part of the implant in the cortical bones, and guarantees optimal primary stability of conical IMPLA implants.
Impla position key long (IPK long),
As part of prosthetic planning, accurately defines the position of the implant in the master model, and guarantees identical implementation during surgery.
IMPLA position key (IPK),
As part of prosthetic planning, accurately defines the position of the implant in the master model, and guarantees identical implementation during surgery.
cutting guideance, 5.3 mm,
Variante:
5 mm
Goes in the 2.0 mm pilot drill, and guides the elbow piece punch, in order to carry out a circular incision in the gingiva.
open-end pick-up,
This open ended wrench is needed for transfer of the implant into the IPK wrench, and insertion via the drilling template. The open ended wrench can also be used for non-contact removal of the implant from the packing, even where the opening of the patient’s mouth is limited (Pick Up technique).
drill guide sleeve 4.25/11.5 mm,
Variante:
4,25 mm / 11,5 mm
The accurate manufacture of the IMPLA 3D drill guide sleeves guarantees the implementation of the planned implant position.
drill guide sleeve thread cutter 4.2/13 mm,
Variante:
4,2 mm / 13 mm
The accurate manufacture of the Impla 3D drill guide sleeves guarantees the implementation of the planned implant position.
drill guide sleeve countersink 4.2,
Variante:
4,2 mm
The accurate manufacture of the IMPLA 3D drill guide sleeves guarantees the implementation of the planned implant position.