hex screwdriver long, width 1.2,

Description

This hexagon screwdriver with ratchet connection has a 1.2 mm hexagon at the tip.

Product number: 637118
Questions about the product? We are glad to be here for you!
Product information "hex screwdriver long, width 1.2,"

The required torque for the retaining screw is exerted with the help of the torque ratchet. This long version of the screwdriver can be used in jaws with teeth, in the anterior area. It has a 1.2 mm hexagon at the tip. A drilled hole for a safety cord is located in the turntable of the screwdriver grip.

Cutsomers also bought

Micro Retention implant 4.2/11.5 mm, sterile, (Hex Connection)
Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment. Benefits: Hex connection for rotation-secure connection between implant and abutment Special micro-thread for very high primary stability Optimised thread design for improved primary stability even in soft bones Integrated Platform Switching to improve the soft tissue attachment Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Details
Micro Retention implant 4.2/9.5 mm, sterile, (Hex Connection)
Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment. Benefits: Hex connection for rotation-secure connection between implant and abutment Special micro-thread for very high primary stability Optimised thread design for improved primary stability even in soft bones Integrated Platform Switching to improve the soft tissue attachment Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Details
Micro Retention implant 5.3/9.5 mm, sterile, (Hex Connection)
Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment. Benefits: Hex connection for rotation-secure connection between implant and abutment Special micro-thread for very high primary stability Optimised thread design for improved primary stability even in soft bones Integrated Platform Switching to improve the soft tissue attachment Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Details
Pilot drill short 2.0 mm,
Total length: 33.5 mmDiameter: Ø 2.0 mm The IMPLA pilot drill will help you determine the planned implant length and insertion vector. You will find the according depth marks on the spiral drills which can be verified with the length mark keys of the surgery tray.The drill collar of the IMPLA pilot drill has been constructed to accommodate the IMPLA depth stops as an addition. The IMPLA depth stops will provide a mechanical depth stop when drilling into the jaw bone for an even higher level of safety in implantology. The drill collar of the IMPLA pilot drill as well as the according depth stop are color-coded. This facilitates a clear and easy handling.
Details
Pilot drill 1.2 mm,
The pilot hole created by the marking drill in the bone guides the tip of the pilot drill which follows, and stops it slipping in difficult to reach areas, and in unfavourably shaped jaw ridges. The drill has laser markings matching the implant lengths and so can also be used as a pilot drill.
Details
Cylindrical (Hex Connection) 3.6/11.5 mm, sterile,
Whether it’s the upper or lower jaw, hard or soft bone - the IMPLA cylindrical implant is the answer to the everyday demands of implantology. The basic cylindrical shape is complemented by synchronous threading to the implant shoulder. In the same way, the surface of the cylindrical implant is sanded and etched to the implant shoulder. Alongside very good primary stability, even in cancellous bones, the cylindrical implant design gives you a high degree of flexibility. In particular, the insertion depth can be adapted very quickly by the surgeon. The self-tapping thread reduces the amount of surgery needed. Integrated Platform Switching ensures better preservation of the marginal bone. Benefits: Hex connection for rotation-secure connection between implant and abutment. Special micro-thread with a pitch of 0.8 mm for very high primary stability. Large Bone Lock for easy insertion and increased removal protection. Integrated Platform Switching to improve the soft tissue attachment. Self-tapping thread for a maximum level of surgical flexibility Microstructured, high-purity surface for optimal cell adaptation and safe osseointegration
Details