Filter
The item has been added to your inquiry list
Alphalink Implant, 2 x 4g cartridge incl. mixing cannula
For bonding titanium abutments to individualized zirconium dioxide abutments and supra-constructions. The full system consists of: Sebond Implant: The bonding agent prepares the zirconium dioxide surface for secure bonding. Alphalink Implant: The fixing composite bonds your framework to the abutment. Indications: Glue individual abutments to the corresponding adhesive base. Use this system for secure adhesion of supra constructions to abutments. Bond the following materials: Zirconium dioxide Precious metal Non-precious alloys Titanium Ceramics Unequaled bond strength values: Zirconium dioxide: >, 20 MPa Titanium: >, 30 MPa Benefits at a glance: The material offers the highest level of safety, as it was especially developed for bonding The system adapts to the user: Intraoral use = quick curing Use on models = longer working range High bond strength Long term stability due to the specially adapated formula Saves time Facilitates accurate work:The pasty consistency lets you remove excess material very easily Content: 2 x 4 g syringe Alphalink Implant, 10 mixing tips
torque wrench 4 Ncm,
Using this torque wrench the inner matrix is screwed into the matrix housing and set onto the patrix. Inner assembly matrices with blue acrylic inserts should not be used as permanent inner matrices in prostheses, they are intended exclusively for use in the dental laboratory.
Sebond Implant, 5 ml bottle
For bonding titanium abutments to individualized zirconium dioxide abutments or supra-constructions. The full system consists of: Sebond Implant: The bonding agent prepares the zirconium dioxide surface for secure bonding. Alphalink Implant: The fixing composite bonds your framework to the abutment. Indications: Glue individual abutments to the corresponding adhesive base. Use this system for secure adhesion of supra constructions to abutments. Bond the following materials: Zirconium dioxide Precious metal Non-precious alloys Titanium Ceramics Unequaled bond strength values: Zirconium dioxide: >, 20 MPa Titanium: >, 30 MPa Benefits at a glance: The material offers the highest level of safety, as it was especially developed for bonding The system adapts to the user: Intraoral use = quick curing Use on models = longer working range High bond strength Long term stability due to the specially adapated formula Saves time Facilitates accurate work:The pasty consistency lets you remove excess material very easily Content: 1 x 5 ml Sebond Implant
Abutment holder set,
Set including an abutment holder (art.no. 635505), adapter pins hex connection (art.no. 635506) and cone connection (art.no. 635507, 635508).
Abutment Holder (red),
The abutment holder facilitates grinding, gluing and individualization of IMPLA abutments by Schütz Dental and avoids damage of the internal connection. The abutment holder can be adapted to our Hex Connection as well as to our Cone Connection by using the corresponding adapter pins. Autoclavable from -40 °C up to 200 °C
activator / deactivator,
Using this wrench, the gold inner matrix can be compressed (activated) or expanded to match the position of the prosthesis.
Locator adapter, with contra-angle connector,
Tool for unscrewing the Locator abutment with contra-angle or as an insert in conjunction with 636077 in the torque ratchet.
key for insertion aid (for ratchet) short, width 3,
Variante:
Schlüssel für Eindrehhilfe kurz, SW 3
The tool’s working tip fits onto the external hexagon of the insertion post. It can be used by hand, or with the torque ratchet. The short version is used for jaws without teeth, or in cases where the mouth opening is limited. A drilled hole safety cord is located in the turntable of the grip.
screwdriver width 2.3 mm, machine-driven
The screwdriver with contra-angle connection offers a 2.3 mm hex connector. With help of the contra-angle, it is used to screw in two-piece IMPLA implants automatically and directly. The screwdriver 2.3 mm fits exactly into the inner hex of the IMPLA Hex Connection implants to insert them. Furthermore, it serves as a screw-in instrument for SAE cone adaptors.
hex screwdriver short, width 1.2,
Variante:
1,2 mm / kurz
The required torque for the retaining screw is exerted with the help of the torque ratchet. This long version of the screwdriver can be used in jaws with teeth, in the anterior area. It has a 1.2 mm hexagon at the tip. A drilled hole for a safety cord is located in the turntable of the screwdriver grip.
hex screwdriver short, width 2.3,
Variante:
kurz
The tool’s working tip grabs directly onto the hexagonal interior of the implant. It can be used by hand, or with the torque ratchet. The short version is used for jaws without teeth, or in cases where the mouth opening is limited. A drilled hole for a safety cord is located in the turntable of the screwdriver grip.
adapter ratchet for Locator adapter contra-angle,
Tool for manual unscrewing the Locator abutment in conjunction with 636075 in the torque ratchet.
contra-angle adapter width 1.2 mm,
Variante:
1,2 mm / universal
This can be used either manually (adapter for elbow instruments 636077) or with the elbow attachment. The short version is used for jaws without teeth, or in cases where the mouth opening is limited. It has a 1.2 mm hexagon at the tip.
Pin Hex Connection 3,3 mm / 4,2 mm / 5,3 mm, for Abutment Holder
Adapter for Hex Connection 3.3/3.6/4.2/4.5/5.3/5.5 mm
Pin Cone Connection 5,3 mm, for Abutment Holder
Variante:
Pin Cone Connection 5,3 mm
Adapter for Cone Connection.