Go to homepage
Home
Company
Dentist
Dental Lab
Media
Contact
Show all Company
History
Career
Show all Dentist
IMPLA
Implants
Prosthetics Mini Implants
Prosthetics Cone Connection
Prothetics Accessories
Prosthetics Hex Connection
Surgery
Drills and Tools
Downloads
Dental Practices
Small Appliances & Accessories
Bleaching
Others
Filling Material
Digital Practice
CAD/CAM Accessories
Blanks
Complete Digital Workflow
3D Implant Navigation
Milling Machines
Plane System
Milling Tools
zebris CMD Measuring and Analysis
Intraoral Scanner
Show all Dental Lab
Bonding System
CAD/CAM
CAD Software
Scanner
CAD/CAM Accessories
Sintering Furnaces
Complete Digital Workflow
Milling Machines
Milling Tools
Blanks
zebris CMD Measuring and Analysis
CAM Software
Dental Labs
Rotating Instruments
Ceramics
Veneering Composites
Equipment
Metals
Electro-Forming
Attachments
Denture Acrylics
Temporary C&B Material
Denture Acrylics
Relinings
Equipment
Denture Acrylics
PCS Denture Colors
Show all Media
News
Newsletter
Videos
Case Studies
Brochures
Safety Data Sheets
Instructions
Show all categories Drills and Tools Back
  • Show Drills and Tools
  1. Dentist
  2. IMPLA
  3. Surgery
  4. Drills and Tools
  • Company
  • Dentist
    • IMPLA
      • Implants
      • Prosthetics Mini Implants
      • Prosthetics Cone Connection
      • Prothetics Accessories
      • Prosthetics Hex Connection
      • Surgery
        • Drills and Tools
      • Downloads
    • Dental Practices
    • Digital Practice
  • Dental Lab
  • Media
  • Contact

Drills and Tools

Filter
The item has been added to your inquiry list
To my inquiry list
torque ratchet,
torque ratchet,
A socket for the different tools, such as screwdrivers and tighteners, is located on the head of the ratchet. It restricts the torque previously set on the tensioning screw - between 0 and 30Ncm - by slipping off the ratchet head. This torque limit can be disabled by twisting the head, in order to tighten implants into the perfect position, for example. The direction of rotation is marked on the ratchet head. We recommend taking the ratchet apart for purposes of cleaning and sterilisation.
Details
Guide key for insertion aid,
Any loosening movement of the implant is prevented by pushing up the outer hexagon on the insertion post when releasing the retaining screw. Furthermore, the insertion post can be loosened if it ever jams.
Details
Locator instrument, three-part,
Locator instrument, three-part,
Screwed stainless steel tip for removing retention inserts, mid section for repositioning the retention inserts, and gold coloured insertion aid for final screwing of the Locator®.
Details
Enlargement drill long 2.75 mm for Cylindrical,
Enlargement drill long 2.75 mm for Cylindrical,
Variante: Erweiterungsbohrer lang 2,75 mm für Cylindrical
Use this extension drill without internal cooling for the preparation of the implant site for IMPLA Cylindrical implants. The suitable drill diameter is selected from the drill protocol depending on implant diameter and drill depth.The drill depth in the bone is controlled with help of the depth marks on the drill. The drills with diameters 3.15 mm and 4.25 mm are available in a short version for use in the molar region.
Details
Enlargement drill short 2.5 mm,
Enlargement drill short 2.5 mm,
Variante: Erweiterungsbohrer kurz 2,5 mm
Extension drill, short, without internal cooling, diameters 2.5 mm, 3.15 mm and 4.25 mm for all IMPLA Micro Retention implant lines.Depth stops are available for all pilot drills and extension drill. These depth stops give the user security and control, even in difficult anatomical situations.
Details
Countersink cutter 3.3 mm,
Countersink cutter 3.3 mm,
Variante: Bettfräser 3,3 mm
Site drill without internal cooling for shaping the implant silhouette in the bone of IMPLA implants Micro Retention or Dual Surface.
Details
Enlargement drill short 2.75 mm for Cylindrical
Enlargement drill short 2.75 mm for Cylindrical
Variante: Erweiterungsbohrer kurz 2,75 mm für Cylindrical
Extension drill short, without internal cooling, diameters 2.75 mm, 3.0 mm, 3.7 mm, 3.9 mm, 4.6 mm and 4.9 mm for all IMPLA Cylindrical implant lines. Depth stops are available for all pilot drills and extension drills. These give the user security and control, even in difficult anatomical situations.
Details
Countersink cutter 3.4 mm for Cylindrical,
Countersink cutter 3.4 mm for Cylindrical,
Variante: Bettfräser 3,4 mm für Cylindrical
Gently prepare the implant site in bones of medium to high hardness. Site drill without internal cooling for shaping the implant silhouette in the bone for IMPLA Cylindrical implants.
Details
Enlargement drill, long
Enlargement drill, long
Variante: 2,5 mm
Use this extension drill without internal cooling for the preparation of implant sites for IMPLA implant lines Dual Surface and Micro Retention. The suitable drill diameter is selected from the drill protocol depending on the implant diameter and the drilling depth.The depth inside the bone is controlled during the drilling process with help of the depth marks on the drill. The drills with the diameters 3.15 mm and 4.25 mm are available in a short version for use in the molar region.
Details
Cortical drill 2.0/3.15 mm,
Cortical drill 2.0/3.15 mm,
Variante: Kortikal-Bohrer 2,0 / 3,15 mm
Without internal cooling. Ideally use on D1 and D2 bones. Cortical drill for the extension of 2 mm pilot drillings to 3.15 mm diameter of the next drill setting in the corticalis.
Details
Pilot drill long 2.0 mm,
Pilot drill long 2.0 mm,
Surgical pilot drill without internal cooling for different drill settings during the preparation of the implant site for the IMPLA implant lines Cylindrical, Dual Surface and Micro Retention (according to the drill protocol, limited use for Mini and Interim).
Details
Pilot drill short 2.0 mm,
Pilot drill short 2.0 mm,
Total length: 33.5 mmDiameter: Ø 2.0 mm The IMPLA pilot drill will help you determine the planned implant length and insertion vector. You will find the according depth marks on the spiral drills which can be verified with the length mark keys of the surgery tray.The drill collar of the IMPLA pilot drill has been constructed to accommodate the IMPLA depth stops as an addition. The IMPLA depth stops will provide a mechanical depth stop when drilling into the jaw bone for an even higher level of safety in implantology. The drill collar of the IMPLA pilot drill as well as the according depth stop are color-coded. This facilitates a clear and easy handling.
Details
Instrument contra-angle,
Instrument contra-angle,
Contra angle-driven 3 mm Allen key for insertion post of IMPLA implants for machine insertion. The key has a snap-in function for implants.
Details
bone thread cutter 5.3 mm,
bone thread cutter 5.3 mm,
Variante: 5,3 mm / universal
Precutting the thread reduces the screw-in torque especially in D1 and D2 bone qualities, to avoid overheating and extreme compression. Use the thread cutter considering the drilling protocol for Micro Retention and Dual Surface implants.
Details
Drill extension,
Drill extension,
 Guarantees comfortable and safe work evenin situations with limited interdental space. For the extension of the tool shaft for contra-angle 2.34 mm.
Details
pilot drill 1.8 mm,
pilot drill 1.8 mm,
The pilot hole created by the pilot drill in the bone guides the tip of the pre-drill which follows, and keeps it from slipping in difficult to reach areas or in unfavorably shaped jaw ridges.
Details
Insertion aid for Mini implant balltop,
Insertion aid for Mini implant balltop,
The tool’s working tip fits over the Torx connector of the Mini Balltop implant. It can be used by hand, or with the torque ratchet. A drilled hole safety cord is located in the turntable of the grip.
Details
hex screwdriver long, width 2.3,
hex screwdriver long, width 2.3,
Variante: lang
This screwdriver with ratchet connection is a 2.3 mm hex and can be used either in connection with the torque ratchet or manually. The screwdriver 2.3 mm fits directly into the inner hex of the IMPLA Hex implants. It is used to adjust the screw-in depth after removing the insertion post (e.g. to correct the position of the hex). What's more, it serves as a screwdriver for SAE cone adapters. The tool has a hole through which it can be secured with a thread.
Details
adapter ratchet for Locator adapter contra-angle,
adapter ratchet for Locator adapter contra-angle,
Tool for manual unscrewing the Locator abutment in conjunction with 636075 in the torque ratchet.
Details
hex screwdriver long, width 1.2,
hex screwdriver long, width 1.2,
Variante: 1,2 mm / lang
The required torque for the retaining screw is exerted with the help of the torque ratchet. This long version of the screwdriver can be used in jaws with teeth, in the anterior area. It has a 1.2 mm hexagon at the tip. A drilled hole for a safety cord is located in the turntable of the screwdriver grip.
Details
screwdriver width 2.3 mm, machine-driven
screwdriver width 2.3 mm, machine-driven
The screwdriver with contra-angle connection offers a 2.3 mm hex connector. With help of the contra-angle, it is used to screw in two-piece IMPLA implants automatically and directly. The screwdriver 2.3 mm fits exactly into the inner hex of the IMPLA Hex Connection implants to insert them. Furthermore, it serves as a screw-in instrument for SAE cone adaptors.
Details
insertion aid (for ratchet) long, width 3,
insertion aid (for ratchet) long, width 3,
Variante: Schlüssel für Eindrehhilfe lang, SW 3
The tool’s working tip fits onto the external hexagon of the insertion post. It can be used by hand, or with the torque ratchet.  This long version of the tightening aid can be used in jaws with teeth, in the anterior area. A drilled hole safety cord is located in the turntable of the grip.
Details
Insertion aid 2.0 mm for Cone Connection 3.3/4.2 mm
Insertion aid 2.0 mm for Cone Connection 3.3/4.2 mm
Variante: lang
Ratchet tool to change the insertion depth or the hex position of IMPLA Cone Connection implants after removal of the insertion post (part of the packaging).The tip of this tool fits precisely into the implant geometry. It can be used manually or with a torque ratchet,.
Details
Insertion aid 2.5 mm for Cone Connection 5.3 mm
Insertion aid 2.5 mm for Cone Connection 5.3 mm
Variante: kurz
Ratchet tool to change the insertion depth or the hex position of IMPLA Cone Connection implants after removal of the insertion post (part of the packaging).The tip of this tool fits precisely into the implant geometry. It can be used manually or with a torque ratchet,.
Details
Depth gauge 6.5 mm - 14.5 mm,
Depth gauge 6.5 mm - 14.5 mm,
For checking the plant implant insertion depth after use of the pilot drill 2 mm and of the extension drill according to the implant diameter. For checking the orientation / divergence of the implants.
Details
Insertion aid machine-driven with contra-angle connector, for Mini balltop
Insertion aid machine-driven with contra-angle connector, for Mini balltop
The tool’s working tip fits over the Torx connector of the Impla Mini Balltop implant. It can be used either manually, (adapter for elbow instruments 636077) or with the contra angle.
Details
contra-angle adapter width 1.2 mm short,
contra-angle adapter width 1.2 mm short,
Variante: 1,2 mm / kurz
This can be used either manually (adapter for elbow instruments 636077) or with the elbow attachment. The short version is used for jaws without teeth, or in cases where the mouth opening is limited. It has a 1.2 mm hexagon at the tip.
Details
Insertion aid long machine-driven 2.0 mm, (for Cone Connection 3.3/4.2 mm)
Insertion aid long machine-driven 2.0 mm, (for Cone Connection 3.3/4.2 mm)
Variante: Eindrehhilfe lang, masch. 2,0 mm
Screwdriver with connection geometry 2 mm for all Cone Connection implants. For making fine adjustments to the implant in the bone after the insertion post which comes with the implant packaging has already been removed (Cone Connection series, diameter 3.3 mm and 4.2 mm). The screwdriver can be used with a contra-angle, manually with the adapter art. no. 636077 or with the torque ratchet.
Details
open-end pick-up,
open-end pick-up,
This open ended wrench is needed for transfer of the implant into the IPK wrench, and insertion via the drilling template. The open ended wrench can also be used for non-contact removal of the implant from the packing, even where the opening of the patient’s mouth is limited (Pick Up technique).
Details
Depth gauge 3.3mm brown,
Depth gauge 3.3mm brown,
Variante: 3,3 mm
For checking the plant implant insertion depth after use of the pilot drill.
Details
  • Partner for over 60 years
    Partner for over 60 years
  • Save cleverly with offers
    Save cleverly with offers
  • Wide product range
    Wide product range
  • Fast delivery
    Fast delivery
  • Competent support
    Competent support
Contact

Fon: +49 (0) 6003 / 814 - 362Fax: +49 (0) 6003 / 814 - 907E-Mail: export@schuetz-dental.deMonday - Thursday from 8 am to 5 pm
Friday 8 am - 4:30 pm

Or via our contact form.
Company and Service
  • About Schütz Dental
  • Brochure Overview
  • Inquiry list
  • Partners
  • Safety Data Sheets
  • Instructions
Legal
  • Data Privacy Statement
  • General Terms and Conditions of Business of Schütz Dental GmbH
  • Imprint
  • Contact

    * All prices excl. VAT plus shipping costs and possible delivery charges, if not stated otherwise.

    This website uses cookies to ensure the best experience possible. More information...